A New Objective Evaluation Tool for Grading Cataract Density Using PENTACAM®
DOI 10.1055/s-2008-1057966
Bibliografische Angaben
Nachweis in CareLit
Autor:innenS Hara, MJ Sanchez, D Vucic, GU Auffarth
ZeitschriftKlinische Monatsblätter für Augenheilkunde
Ausgabe02/2008
Jahrgang / SeitenNicht angegeben
Kernaussage aus der Literatur
Abstract-Vorschau
Purpose: To grade the density of cataract objectively using a rotating Scheimpflug camera and to investigate the correlation between the grade of the density and the total phaco energies at the phacoemulsification. Methods: In this study, one hundred eighty six eyes of 166 consecutive patients undergoing phacoemulsification for cataract using Infinity (Alcon, US) by only one surgeon were preoperatively examined with…
Zitieren
Zitierempfehlung
S Hara, MJ Sanchez, D Vucic, GU Auffarth (2008) A New Objective Evaluation Tool for Grading Cataract Density Using PENTACAM®. Klinische Monatsblätter für Augenheilkunde (02). https://doi.org/10.1055/s-2008-1057966