CareLit Fachartikel

Effective fetal cardiac massage during fetal cardiac intervention gone wrong

T Kohl, J Degenhardt, R Axt-Fliedner · Ultraschall in der Medizin - European Journal of Ultrasound · 2013 · Heft 10

Dokument
1081873
CareLit-ID
Jahr
2013
Publikation
PDF
nein
Metadaten
DOI
ja
zitierfähig

Bibliografische Angaben

Zeitschrift
Ultraschall in der Medizin - European Journal of Ultrasound
Autor:innen
T Kohl, J Degenhardt, R Axt-Fliedner
Ausgabe
Heft 10 / 2013
Seiten
–
Erschienen: 2013-10-14 00:00:00
ISSN
0172-4614

Zusammenfassung

Background: Fetal cardiac arrest may occur as a complication of ultrasound-guided fetal cardiac interventions. Case: Ultrasound-guided fetal septoplasty via an 18-gauge needle was performed in a human fetus with aortic atresia at 23+6 weeks of gestation because of a non-patent atrial septum associated with severe pulmonary congestion. Following successful creation of an opening by laser energy, a micro-grasper was inserted via the needle shaft and an even larger opening in the atrial septum was achieved. As a result, complete alleviation of pulmonary congestion was observed. Unfortunately, at this time, the micr…

Schlagworte

Ultraschall in der Medizin - European Journal of Ultrasound