CareLit Fachartikel

Healthy controls have the same hepatic transit time (HTT) using SonoVue® and Luminity® but using Levovist® the HTT is significantly longer

T Haendl, D Strobel, K Esser, M Frieser, T Bernatik · Ultraschall in der Medizin - European Journal of Ultrasound · 2007 · Heft 10

Dokument
1106631
CareLit-ID
Jahr
2007
Publikation
PDF
nein
Metadaten
DOI
ja
zitierfähig

Bibliografische Angaben

Zeitschrift
Ultraschall in der Medizin - European Journal of Ultrasound
Autor:innen
T Haendl, D Strobel, K Esser, M Frieser, T Bernatik
Ausgabe
Heft 10 / 2007
Seiten
–
Erschienen: 2007-10-10 00:00:00
ISSN
0172-4614

Zusammenfassung

Objective: Liver metastases lead to a shortening of the HTT of an echo enhancer. Former studies using Optison® showed a HTT of about 16s in healthy controls. Optison is currently unavailable and recent observations indicated that SonoVue® has a shorter HTT than Optison®. Hence we compared the HTT of present available contrast agents in healthy controls. Method: 15 healthy controls with no visible liver lesions were enrolled in this study. We measured the HTT of three echo enhancers (SonoVue®, Luminity® and Levovist®), using low MI and CPS of Acuson sequoia®. The hepatic artery and a branch of the hepatic vein we…

Schlagworte

Lead Ultraschall in der Medizin - European Journal of Ultrasound