CareLit Fachartikel

High-Quality, High-Throughput, Early Whole-Body Bone Scanning

N.N. · Nuklearmedizin - NuclearMedicine · 1977 · Heft 05 · S. 238-240

Dokument
1212508
CareLit-ID
Jahr
1977
Publikation
PDF
nein
Metadaten
DOI
ja
zitierfähig

Bibliografische Angaben

Zeitschrift
Nuklearmedizin - NuclearMedicine
Autor:innen
N.N.
Ausgabe
Heft 05 / 1977
Jahrgang 16
Seiten
238-240
Erschienen: 1977-05-01 00:00:00
ISSN
0029-5566

Zusammenfassung

Summary 99m Tc-IDP allows for high-quality, high-throughput and early whole-body bone scanning. Whole-body bone scans obtained at 30 min after intravenous administration of the tracer were compared with the standard and delayed 180 min p. i. images. A subtraction technique allowed for the analysis of the 30 min scans and it was found that in both types of investigation the same clinical information was present. This procedure will therefore increase considerably the throughput of whole-body bone scans in a busy department of nuclear medicine. It is however inadequate for detailed analysis of the skeleton (evalua…

Schlagworte

After Nuklearmedizin - NuclearMedicine