Visuelle Beurteilung von Tumorgrößenveränderungen im CT – Eine Pilotstudie
HM Knabe, A Wulff, M Tepper, S Ritter, JP Schaefer, O Jansen · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 2014 · Heft 04
Bibliografische Angaben
Zusammenfassung
Zielsetzung: When assessing tumor response to therapy on CT, one frequently observes tumor changes that lie within RECIST boundaries of stable disease (-30%/+20%). We investigated the minimum lesion change that radiologists are able to detect without measuring. Material und Methodik: Computationally generated lesions (50 HU, range 9 to 33 mm) were displayed on a plain background (-750 HU) in a baseline and follow up fashion simulating lung CT examinations. White noise was added (bandwidth ± 100 HU). Diameter changes were experimentally manipulated to range from – 30% to + 20% at follow up. Images (63 cases, 124…