CT-angiography before TAVI using high-pitch spiral acquisition mode
S Gauß, S Achenbach, A Schuhbaeck, M Arnold, M Marwan, WG Daniel, S Ensminger · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 2012 · Heft 01
Bibliografische Angaben
Zusammenfassung
Introduction: Preparation for transcatheter aortic valve implantation (TAVI) requires imaging of the aortic root, aorta, and iliac arteries. Contrast agent exposure can be a problem in TAVI candidates who often have impaired renal function. High-pitch spiral CT allows high-resolution imaging of large volumes in a very short time. We evaluated the ability of high-pitch spiral imaging with dual source CT (“Flash Mode”) and a minimized amount of intravenous contrast to evaluate aortic root anatomy and suitability of vascular access for TAVI procedures. Methods: 25 patients (15 female, 10 male, mean age 82±7 years,…