US B-mode and CEUS (Contrast-Enhances Ultrasound) patterns in n = 62 patient with traumatic and spontaneous non-traumatic (n = 33) and traumatic (n = 29) splenic ruptures: a compe…

M Rosling, C Görg · Ultraschall in der Medizin - European Journal of Ultrasound · 2016 · Heft 08

Dokument
989060
CareLit-ID
Jahr
2016
Publikation
PDF
nein
Metadaten
DOI
ja
zitierfähig

Bibliografische Angaben

Zeitschrift
Ultraschall in der Medizin - European Journal of Ultrasound
Autor:innen
M Rosling, C Görg
Ausgabe
Heft 08 / 2016
Seiten
–
Erschienen: 2016-08-18 00:00:00
ISSN
0172-4614

Zusammenfassung

Introduction: Both US B-mode and CEUS are well established procedures when diagnosing traumatic splenic ruptures (TSR). It is uncertain whether spontaneous splenic ruptures (SSR) and TSR differ concerning clinic, B-Bild and CEUS pattern and prognosis. Material and methods: Between 12/2003 and 2/2010 n = 33 SSR and n = 29 TSR were diagnosed in an medical universitary ultrasound laboratory. All patients were examined with B-Bild and CEUS. Clinical data, US B-mode and CEUS pattern incl. Grading and course were retrospectivly analysed and compared. Results: There were significant differences concerning clinical data…