Clinical outcome and patient reported performance of a partial-range of focus (RoF) IOL after bilateral implantation
Thomas Kohnen, Kerstin Petermann, Eva Hemkeppler, Christoph Lwowski, Myriam Böhm · Klinische Monatsblätter für Augenheilkunde · 2026 · Heft 10
Bibliografische Angaben
Zusammenfassung
PURPOSE: To evaluate the visual performance after bilateral implantation of a diffractive partial range of focus intraocular lens (RoF IOL) with a smooth microphase (SMP)-technology for less light scattering. DESIGN: Prospective case series METHODS: Twenty patients (40 eyes) received bilateral implantation of a partial RoF IOL (AT LARA 829MP, Carl Zeiss Meditec, Germany) pre-enrolment. Exclusion criteria were previous ocular surgeries other than cataract surgery and refractive lens exchange, postoperative complications, ocular pathologies or corneal abnormalities. 3 months’ postoperative examination included man…